Connectivity

Connect the machines and systems you already run.

Connectors read and write data in PLCs, databases and IT systems such as MES and ERP. Heisenware builds, tests and maintains every one. The Assistant sets them up for you. So does your own AI client via MCP.

Show all connectors

Every connector, in one list.

Each connector reads and writes one kind of machine or system.

  • Machines and controls

    • Siemens S7, from S7-300 to S7-1500
    • Allen-Bradley via EtherNet/IP
    • Modbus TCP and RTU
    • Bosch Rexroth ctrlX CORE and COREvirtual
    • Heidenhain CNC controls via OPC UA and DNC
    • Serial devices via RS-232 and RS-485
    • Older machines, retrofitted with a digital signal counted on a Raspberry Pi
  • Protocols and interfaces

    • OPC UA client, signed and encrypted with certificates
    • OPC UA server with your own information model
    • MQTT client for any broker over TCP, TLS or WebSockets
    • Built-in MQTT broker
    • HTTP, REST and GraphQL
  • IT systems

    • MPDV Hydra 8 and Hydra X on MIP
    • SAP
    • Other ERP and MES via REST, GraphQL, SQL or files
    • Email with attachments
  • Databases and files

    • PostgreSQL, MySQL, MariaDB, Microsoft SQL Server, SQLite, Oracle and Snowflake
    • InfluxDB for time series
    • CSV, Excel, Word, PDF and XML files, also on a file server
    • Fill PDF templates and make barcodes and QR codes
  • Devices and hardware

    • Zebra fixed RFID readers: FX7500, FX9600 and ATR7000
    • Network label printers with templates such as ZPL
    • Barcode and QR scanning with the device camera
    • USB status lights (Kuando Busylight)
    • Server health: CPU, memory, disk, network and containers

Connect systems across network boundaries.

Machines and IT systems often sit behind a firewall or in a separate network. Heisenware reaches them through an agent. The agent runs in that network and opens the connection to Heisenware from inside. Data then flows both ways. No inbound ports, no VPN.

Read how agents work

An agent is the bridge to your machines and systems.

An agent is a small program that you build in Heisenware and install next to your machines. The connectors you pick run inside it, in the same network as your machines. Heisenware calls them through the agent, so your apps can read a PLC or write to a local database. You update and restart agents remotely and manage many of them as one fleet.

Read the agent docs

The Build agent dialog of the App Manager. A list of twenty connectors with checkboxes, from Allen Bradley PLC to Trusted Certificates. File I/O, Kuando Busylight, OPC UA Client and Operating System are ticked.
The installer of an agent in the App Manager: a ZIP file of 96 MB for Windows, when it was built, and a download link with the buttons Copy and Download.

Machine not connected yet? Simulate the data.

Heisenware simulates a CNC machine, a pump, a conveyor and more, with values that behave like real ones. Trigger a fault and watch your alarm go off. Once the machine itself is connected, the same app runs on live data.

FAQ

Which machines and systems does Heisenware connect to?

Heisenware connects to Siemens S7, Allen-Bradley, Modbus, ctrlX and Heidenhain controls. Anything that speaks OPC UA or MQTT connects too. On the IT side: MPDV Hydra, SAP, SQL databases, InfluxDB, REST, GraphQL and files. Heisenware is an industrial application platform. Its connectors bring this data into the real industrial software you build by prompt.

What if our system is not on the list?

Most machines and systems connect through a standard that Heisenware already speaks: OPC UA, MQTT, Modbus, REST, GraphQL, SQL or files. If a connector is missing, you build it yourself or we build it for you. It then works like any other connector in the platform.

Can old machines without an interface be connected?

Yes, with a small retrofit. A Raspberry Pi counts a simple signal such as the machine's run lamp and detects run and stop. Serial devices connect via RS-232 or RS-485. All of them end up in the same apps as the newest controls.

Can apps also write to a machine or an IT system?

Yes. Connectors read and write. An app can set a value in a PLC or write a record back to your ERP.

Which ports does the agent need?

Nothing inbound. The agent connects outbound over encrypted MQTT (MQTTS) on TCP 8883. While an update downloads, it also uses TCP 443 to the same host. No VPN. Every agent build comes with a requirements sheet for IT.

Where does the agent run?

On hardware you already have: a Windows or Linux PC, a ctrlX CORE, a Docker gateway or an INSYS router. You need no extra industrial PC.

Do we have to update every agent one by one?

No. Agents that belong together form a fleet. A new build rolls out to the whole fleet, at once or in batches, at a time you set. If an update fails, the agent switches back on its own. You can also restart an agent remotely.

Build your own manufacturing software today.

Get the complete platform to take industrial software development into your own hands.